Functional characteristics
1. Enable the function in sequence and disable the function in reverse order
2. The PASS key enables all channels at the same time
3.3.com interface access control (command control) or its own software control
4. The time interval is adjustable
5. Number of channels: 8 universal socket relays controlled
6. Cascade machine ID:0-255
7. The panel channel is closed independently, and the interval/timing time of each switch is 1 second by default (set freely by software).
8. Output relay contact current: 30A 277VAC
9. Circuit board specifications: double-sided fiberboard, main power line thickening and coarse processing
10. Power supply specifications: Built-in switching power supply, suitable for global voltage AC90-260V 50-60HZ
11. Open type: touch button switch, single independent switch function: support panel independent control (software setting control)
12. Output power socket specifications: flame retardant ABS material, phosphorus copper material, standard universal socket
13. External control switch interface: RS232 COM interface
14. Random control software and support central control function and ID quantity allocation: comes with command code and control software
15. Power purification function (EMI professional power grid filter) : none (optional single or per band filter)
16. Short-circuit overcurrent protection Circuit breaker configuration: circuit breaker fireline control overcurrent protection (40A short-circuit protection))
Technical parameter
Input power supply: AC90-260V 50-60HZ
Relay: 30A/250AC
Temperature range: -5℃ to +40℃
Humidity range: 0 to 90%RH
Control output: 232 serial port